INFLUENCE OF BOILING TEMPERATURE ON THE PANELS LVL (LAMINATED VENEER LUMBER) QUALITY MADE WITH OAK (CANARIENSIS) ALGERIA WOOD
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
The panels LVL (Laminated Veneer Lumber) are less used in construction, which are
produced by peeling trunk of trees, undergone baking operation which one determined the
quality of plating and LVL panels made by gluing. Our study here consist to vary the boiling
temperatures ranging from 40C°, 50 C°, 60 C°, to 70 C° (two panels are drawn for each
temperature, and 14 specimens (20 * 20 * 336mm) for each panels) that was secure settings
peeling, speed of rotation of the lathe, pressure bar, clearance angle of the knife and the
thickness of the veneer, as we fix the amount of glue 400g / cm2
, the pressure pressing the
panels in order to clearly identify the influence of baking temperature logs of Algerian oak
wood quality. Our controls are carried out by non-destructive testing after that the specimens
are tested with destructive method under four point bending, according to the perpendicular
direction and parallel plating, and we took into consideration the calculation of Young's
modulus and stress at break for each series of panels.